Skip to content
Logo
×
Find a Distributor Request a Quote
  • Products
    • Pressure Regulators
    • Back Pressure Regulators
    • Filter Regulators
    • Gas Regulators
    • Precision Pressure Regulators
    • Pressure Regulators
    • Stainless Steel Pressure Regulators
    • Potable Water Pressure Regulators
    • Brackets, Gauges, & Accessories
    • Electronic Pressure Regulators
    • Pressure Transducers
    • I/P Transducers (current-to-pressure)
    • E/P Transducers (voltage-to-pressure)
    • P/I Transducers (pressure-to-current)
    • I/PAC Integrated Process Air Control
    • Supply Manifold
    • Brackets, Gauges, & Accessories
    • Diaphragm Air Cylinders
    • Rolling Diaphragm Cylinder
    • Small Bore Compact Cylinder
    • Mini Might Cylinders
    • Pneumatic Air Filters
    • Air Relays
    • Vacuum Regulators
    • Valve Positioners
    • Volume Boosters
    • Stainless Steel Volume Boosters
    • No-Brass Products
    • View All Products
  • Custom Solutions
  • Industries
    • Food and Beverage Processing Markets
    • Control Valve Products
    • Oil & Gas Markets
    • Waste Water Processing and Treatment
    • View All Industries
  • Engineers
  • Resources
    • Blog
    • CAD Models & Product Specifier
    • Certifications
    • Catalogs
    • FAQ
    • How to Determine the Appropriate Regulator
    • Instruction Manuals
    • Product Selection Guides
    • Visual Product Reference Guides
    • Videos
    • Volume Booster Sizing Guide
    • White Papers
  • Contact
    • Request a Quote
    • Ask an Expert
    • Contact
    • Request Help From Our Sales Team
  • About
    • About Us
    • News
    • Who We Help
    • Career Opportunities
  • Find a Distributor
  • Request a Quote
(603) 886-9400 | Distributor Login

The Importance of In-Place Transducer Calibration

I/P transducer calibration should be checked after installation because mounting orientation, handling, and operating conditions can affect the relationship between electrical input and pneumatic output. Factory calibration establishes the initial settings; an installation check confirms that the transducer performs as required in its actual application.

This is particularly important for open-loop transducers whose mechanical operating elements can respond to changes in mounting position. Always follow the instructions for the specific model, pressure range, and operating mode.

What Is In-Place I/P Transducer Calibration?

In-place calibration means checking and, where required, adjusting a current-to-pressure transducer in its installed orientation using the specified supply conditions.

The check compares a known electrical input with the measured pneumatic output. If the output does not meet the required values, the manufacturer’s procedure explains how to adjust zero and span.

For example, a direct-acting transducer configured for 4–20 mA input and 3–15 psig output should produce the corresponding pressures shown below.

Input CurrentExpected OutputCheck Point
4 mA3 psigLower endpoint
12 mA9 psigMidpoint
20 mA15 psigUpper endpoint

These values illustrate one configuration. Different output ranges, reverse-acting operation, and split-range settings require different expected values.

Why Can Mounting Position Affect Calibration?

The ControlAir Type 500 and Type 550 use a coil-and-flexure mechanism to control pilot pressure. Electrical current produces a magnetic force that moves the flexure relative to a nozzle, changing the pneumatic output.


ControlAir Type 500 I/P transducer cutaway identifying the magnet, coil, flexure, nozzle, and supply valve
The Type 500 uses a coil, flexure, and nozzle to control pneumatic output. Click the drawing to enlarge.

Gravity also acts on the moving components. Changing the unit’s orientation changes the direction of gravity relative to the operating mechanism and can shift the output produced by a given electrical input.

Checking the transducer in its final mounting position helps identify that shift. The Type 550X instructions specifically state that the unit must be calibrated in the plane in which it is mounted.


Type 500 vertical mounting diagram showing gravitational and magnetic force directions
Vertical orientation
Force directions shown for the illustrated mounting position. Click to enlarge.

Type 500 horizontal mounting diagram showing the changed relationship between gravitational and magnetic forces
Horizontal orientation
Rotating the unit changes gravity’s direction relative to the mechanism. Click to enlarge.

What Else Can Affect Calibration After Installation?

Factory calibration takes place under defined conditions. Installation can introduce different supply pressure, temperature, pneumatic loading, or flow conditions. Handling during transport can also affect calibration settings.

Before adjusting the transducer, confirm that the supply air, electrical signal, connections, and operating conditions meet the product specifications. Calibration adjustments should not be used to compensate for an unsuitable installation or a restricted air supply.

What Do Zero and Span Adjustments Do?

Zero sets the output at the lower electrical-input endpoint. For a 4–20 mA, 3–15 psig direct-acting configuration, that means setting 3 psig at 4 mA.

Span adjusts the input-to-output relationship so that the upper endpoint reaches the specified pressure. In the same example, the upper endpoint is 15 psig at 20 mA.

After a span adjustment, recheck zero. The Type 550X and Type 900X procedures call for repeating the endpoint checks until both are correct. Adjustment directions vary by model and input type, so use the relevant manual.

Do Closed-Loop I/P Transducers Need Calibration Checks?

Closed-loop models such as the ControlAir Type 900X and Type 950XP use internal pressure feedback to correct output deviations. The Type 900X also has no measurable mounting-position effect according to its product specifications.

However, closed-loop feedback does not eliminate installation checks or the manufacturer’s calibration instructions. The Type 900X manual recommends checking calibration and includes zero and span adjustment procedures.

Check the instructions whenever changing the operating mode, pressure range, or configuration.

How Is Calibration Checked?

Use a suitable electrical signal source and pressure reference, with the transducer mounted and supplied as specified in its instructions.

Check the lower and upper input endpoints, make adjustments where required, and recheck the results. Intermediate readings can help confirm the expected input-to-output relationship.

Follow the model-specific procedure and the site’s process-isolation requirements before changing a signal that could move connected equipment.

  • Type 500 product information and instructions
  • Type 550X installation and calibration instructions
  • Type 900X installation and calibration instructions
  • Type 950XP product information and instructions

For help checking an installed transducer, contact ControlAir at [email protected] with the model number, input signal, output range, mounting orientation, and application conditions.

 

 

 

 

 

 

 

 

 

 

Post navigation

 Product Discontinuation NoticePneumatic Steam Valve Control: How the Components Work Together 

Ask an Expert

Contact our technical experts for help with your pneumatic application or ControlAir Product.

Question

First Name*

Last Name*

Email*

Company*

Country*

State/Province*

City*

How did you hear about us*

Click here if you want to be on our mailing list

I accept the terms of our Data Privacy Policy.

Data Privacy Policy

ControlAir’s purpose to collect any personal data is to respond to your request for product help, quotation and processing of orders. We take your privacy seriously. Here are some relevant questions and answers regarding our collection and use of personal data.

What information is being collected?

ControlAir will collect names, email addresses, phone numbers and local addresses so we may fulfill your request for product help, quotes or order shipment.

Who is collecting it?

ControlAir has a sales and marketing department that oversees the collection and use of this data. We do use a Customer Relationship Management system to process this information.

How is it collected?

Data is collected using our Webforms (Get a Quote, Ask the Expert, White Paper Sign Up, etc), via phone calls, incoming emails and during any email campaigns that are sent to you for marketing purposes.

Why is it being collected?

This information is being collected for the purpose to respond to your request and for later follow up to ensure that we provided you with a good customer experience. This information may be used to contact you in the future regarding ControlAir products.

How will it be used?

This information will be entered into a CRM database, so we can contact you via email, phone or mail to fulfill your request and follow up with appropriate product information.

Who will it be shared with?

Your information will not be sold to a third party. Your information maybe shared with one of our local partners (distributors and/or local field agent) so we can fulfill your request for product information and quotation.

What will be the effect of this on the individuals concerned?

The purpose of transferring this information to these individuals/companies will be to fulfill your request for product information and quotation. You may receive emails to alert you of order, quote or shipment status. You may also receive follow up emails to gauge your customer experience and alert you to product information.

Is the intended use likely to cause individuals to object or complain?

We do not expect individuals to object with the use of this data to fulfill an action that they requested of ControlAir. We will remove persons from any future emails if they choose to opt out of future emails.

Please let us know if you have any further questions regarding the processing and use of your information. We can be reached at 1-603-886-9400 or by email at [email protected]

Lead Source

Enter the Captcha*

captcha Reload
Call (800) 216-3636

Related Products

  • Type 500 Electro-Pneumatic I/P Transducer (I/P, E/P)

  • Type 595XP Explosion-Proof I/P Transducer

  • Type 900X Miniature I/P, E/P Transducer

Sign up for the ControlAir newsletter.

Get news, updates, and offers direct to your inbox.

Industries We Serve
  • Food & Beverage
  • Oil & Gas
  • Control Valve
  • Water Treatment

Products

  • Pressure Regulators
  • Back Pressure Regulators
  • Filter Regulators
  • Precision Pressure Regulators
  • Pressure Regulators
  • Stainless Steel Pressure Regulators
  • Potable Water Pressure Regulators
  • Brackets, Gauges, & Accessories
  • Electronic Pressure Regulators
  • Pressure Transducers
  • I/P Transducers (current-to-pressure)
  • E/P Transducers (voltage-to-pressure)
  • P/I Transducers (pressure-to-current)
  • I/PAC Integrated Process Air Control
  • Supply Manifold
  • Brackets, Gauges, & Accessories
  • Diaphragm Air Cylinders
  • Rolling Diaphragm Cylinder
  • Small Bore Compact Cylinder
  • Mini Might Cylinders
  • Pneumatic Air Filters
  • Air Relays
  • Vacuum Regulators
  • Valve Positioners
  • Volume Boosters
  • Stainless Steel Volume Boosters
  • No-Brass Products
  • View All Products
Resources
  • Blog
  • CAD Models
  • Certifications
  • Catalogs
  • FAQ
  • How to Determine the Appropriate Regulator
  • Product Selection Guides
  • Whitepapers
  • Visual Product Reference Guide
  • Videos

ControlAir

International HQ
8 Columbia Dr
Amherst, NH 03031 USA

603-886-9400
1 (800) 216-3636
Send us a message


Privacy Policy | Site Map | © 2019 ControlAir. All rights reserved

We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept”, you consent to the use of ALL the cookies.
In case of sale of your personal information, you may opt out by using the link Do not sell my personal information.
Cookie settingsACCEPT
Manage consent

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
CookieDurationDescription
cookielawinfo-checkbox-analytics11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checkbox-functional11 monthsThe cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checkbox-necessary11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-others11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-performance11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
viewed_cookie_policy11 monthsThe cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Performance
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Analytics
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
Advertisement
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.
Others
Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet.
Save & Accept